ENGLISH
10
Cleaning the Nose Equipment or Replacing
Jaws (Fig. A, J)
1. Loosen the nose housing nut
4
. Remove the nose
housing
3
and nose housingnut.
2. Clean the inside of the nose housing using a drycloth.
3. Pull back the locking sleeve
15
as indicated by the
arrow.
4. Untighten the pulling hull
16
.
5. Clean the jaws
17
and the jaw pusher using a dry cloth.
If necessary, replace the jaws with spare jaws
13
.
NOTE: When replacing the jaws, use only DeWALT
brandjaws.
6. Apply grease to the outside of the clamping jaw
assembly
17
.
7. Put the jaw assembly
17
into the pulling hull
16
and
mount it onto the tool. Tighten the pulling hull by hand
and ensure it is secured by the locking sleeve
15
.
NOTE: A molybdenum disulfide‑based grease
isrecommended.
Cleaning
WARNING: Blow dirt and dust out of all air vents with
clean, dry air at least once a week. To minimize the risk
of eye injury, always wear ANSI Z87.1 approved eye
protection when performing thisprocedure.
WARNING: Never use solvents or other harsh
chemicals for cleaning the non‑metallic parts of the
tool. These chemicals may weaken the plastic materials
used in these parts. Use a cloth dampened only with
water and mild soap. Never let any liquid get inside the
tool; never immerse any part of the tool into aliquid.
Maintenance Frequency
Item Frequency
General tool inspection Daily
Clean and lubricate nose equipment 5000 rivets
*Recommend contacting authorized service center
MAINTENANCE
WARNING: To reduce the risk of serious personal
injury, turn unit off and remove the battery pack
before making any adjustments or removing/
installing attachments or accessories. An
accidental start‑up can causeinjury.
Your DeWALT power tool has been designed to operate
over a long period of time with a minimum of maintenance.
Continuous satisfactory operation depends upon proper tool
care and regularcleaning.
Installing a Blind Rivet (Fig. G)
To Install a Blind Rivet
1. Place the blind rivet
18
in the nose piece
1
.
2. Position the tool as shown in Proper HandPosition.
3. Pull and hold the trigger switch
9
until the rivet is fully
set in theapplication.
4. When the blind rivet has been set completely, release
the trigger switch. The tool will return to its initial
positionautomatically.
5. Tilt the unit backwards and the mandrel will go to the
mandrel collector
5
by gravity. The mandrel will also
LED Worklight (Fig. A)
CAUTION: Do not stare into the LED. Serious eye
injury couldresult.
When the tool is activated by pressing the trigger switch
9
,
the LED worklight
10
will automatically turn on. The LED
worklight will turn off 60seconds after the trigger switch has
beenreleased.
The LED worklight
10
will flash slowly when the battery
state of charge is low.
The LED worklight
10
will flash fast if the nose equipment
is clogged. Refer to Cleaning the Nose Equipment or
Replacing Jaws for the proper cleaningprocedure.
Proper Hand Position (Fig. I)
WARNING: To reduce the risk of serious personal
injury, ALWAYS use proper hand position as shown.
WARNING: To reduce the risk of serious personal
injury, ALWAYS hold securely in anticipation of a
suddenreaction.
Proper hand position requires one hand on the main
handle
8
.
Installing and Removing the Battery Pack
(Fig. H)
WARNING: Ensure the tool/appliance is in the off
position before inserting the batterypack.
NOTE: For best results, make sure your battery pack is
fullycharged.
1. To install the battery pack
11
into the tool handle, align
the battery pack with the rails inside the tool’s handle
and slide it into the handle until the battery pack is firmly
seated in the tool and ensure that it does notdisengage.
2. To remove the battery pack from the tool, press the
battery pack release button
12
and firmly pull the
battery pack out of the tool handle. Insert it into
the charger as described in the charger section of
thismanual.
OPERATION
WARNING: To reduce the risk of serious personal
injury, turn unit off and remove the battery pack
before making any adjustments or removing/
installing attachments or accessories. An
accidental start‑up can causeinjury.
be pushed into the mandrel collector by pulling the
nextrivet.
If you release the switch before the end of the setting
stroke, the tool will immediately return to its initial position.
If the blind rivet has not been set completely, repeat the
previoussteps.