Cleaning and maintenance en
39
6. Carefully unscrew the pump cover,
residual water may leak out.
Clean the interior, pump cover
thread and pump housing. The
impeller in the detergent solution
pump must be able to rotate.
Refit the pump cover and screw it on
tightly. The handle must be in a
vertical position.
7. Place the service flap back on, lock
it into place, and close it.
Note: To prevent unused detergent
from flowing straight into the drain
during the next wash, pour 1 litre of
water (without detergent) into
compartment II and start the 0 Spin
programme. Do the next wash as usual.
The drain hose at the siphon
is blocked
1. Switch off the appliance.
2. Disconnect the mains plug.
3. Loosen the hose clamp. Carefully
remove the drain hose; residual
water may leak out.
4. Clean the drain hose and siphon
connecting piece.
5. Reattach the drain hose and secure
the connection using the hose
clamp.