Changing the HEPA/Carbon Filter
It is important to change the HEPA/Carbon
Filter regularly. The Replace Filter light,
which is the Fan Speed 1 light, will glow
yellow after 6 months, letting you know
that you SHOULD change the lter. When
it turns red after a year, you MUST change
the lter.
1. Turn the OxyPure off and unplug it.
2. Take the OxyPure outside or into a well
ventilated area.
3. Wearing a disposable mask and rubber
gloves, open the Filter Access Lid and
remove the old HEPA/Carbon Filter, plac-
ing it in a plastic garbage bag along with
the gloves for disposal.
4. Unwrap the new HEPA/Carbon Filter and
insert it into the Filter Holder.
5. Securely close the Filter Access Lid.
6. Place the unit where you wish, plug it in
and turn it on.
7. To reset the Replace Filter light, press
and hold Power. There will be 2 short
beeps and the Fan Speed 1 light will turn
white.
Cleaning the OxyPure
Depending on the environment, you may
need to clean the OxyPure more often to
maintain the nish and function of the unit.
Remove the dirty HEPA/Carbon Filter
and place it in a garbage bag.
Wash the vented body of the unit with
warm, soapy water, and dry thoroughly
before inserting a clean HEPA/Carbon
Filter.You can use a gentle, non-abrasive
cleaner, but apply it to the cloth, not to
the unit.
Make sure the vents are free of any
obstruction.
MAINTAINING THE OXYPURE
The OxyPure Does Not Turn On.
1. The unit is not plugged-in. Plug the unit
into an appropriate wall outlet.
2. POWER on the control panel is OFF.
Press POWER.
The Fan Speed Doesn’t Change.
There may be an issue with the control
panel button. Contact Customer Service for
assistance.
Airow From the Top Vent is Weak.
The HEPA/Carbon lter is dirty. Change the
lter.
The Unit Produces Smoke or Odor.
The HEPA/Carbon lter is dirty. Change
the lter.
If any of these problems persist, contact
NuWave’s friendly and knowledgeable
Customer Service Team at 1-877-689-2838,
Monday through Friday from 7:30am to
4:30pm,(CST) or via email at
help@nuwavenow.com.
TROUBLESHOOTING GUIDE
TURN UNIT UPSIDE DOWN
OPEN THE LID TO CHANGE THE FILTER
After 6 MonthsWith in 6 Months After 12 Months
Clean the Motor housing on all side-
sides, using the brush attachment for
your vacuum cleaner or a damp cloth or
sponge. Dry it thoroughly before reas-
sembly.
DO NOT immerse this component in
water.
Reassemble the OxyPure.