INSTALLATION
REQUIREMENTS
Ibols
and
Parts
Gather
the
required
tools
and
parts
before
starting
installation.
Read
and
follow
the
instructions
provided
with
any
tools
listed
here.
Tools
needed
■
Level
■
Drill
with
VA"
(3.0
cm),
%"
(9.5
mm),
and
Yib"
(7.9
mm)
drill
bits
■
Pencil
■
Wire
stripper
or
utility
knife
■
Tape
measure
or
ruler
■
Pliers
■
Caulking
gun
and
weatherproof
caulking
compound
■
Vent
clamps
■
Jigsaw
or
keyhole
saw
■
Flat-blade
screwdriver
■
Metal
snips
■
Phillips
screwdriver
■
Metric
hex
key
set
Parts
needed
■
Home
power
supply
cable
■
V
2
"
(12.7
mm)
UL
listed
or
CSA
approved
strain
relief
■
SUL
listed
wire
connectors
For
vented
installations,
you
will
also
need:
■
1
wall
or
roof
cap
■
Metal
vent
system
For
non-vented
(recirculating)
installations,
you
will
also
need:
■
Recirculation
Kit
Part
Number
W1
0349327
for
non-vented
(recirculating)
installations
only.
See
“
Assistance
or
Service
”
section
to
order.
■
6"
(15.2
cm)
dia.
round
metal
vent
duct
-
length
required
is
determined
by
ceiling
height.
Parts
supplied
Remove
parts
from
packages.
Check
that
all
parts
are
included.
■
Hood
canopy
assembly
with
ventilator
and
light
bulbs
installed
■
Vent
transition
with
back
draft
dampers
installed
■
Metal
grease
filter(s)
■
Vent
cover
support
bracket
■
Mounting
template
■
2-piece
vent
cover
■
2
-
3.5
X
9.5
mm
screws
■
2
-
2.9
X
6.5
mm
screws
■
6
-
5
X
45
mm
mounting
screws
■
2
-
8
X
40
mm
wall
anchors
■
4
-10
X
50
mm
wall
anchors
■
T20®
Torx®t
adapter
©tTORX
and
T20
are
registered
trademarks
of
Saturn
Fasteners,
Inc.
IMPORTANT:
Observe
all
governing
codes
and
ordinances.
Have
a
qualified
technician
install
the
range
hood.
It
is
the
installer's
responsibility
to
comply
with
installation
clearances
specified
on
the
modei/serial
rating
plate.
The
model/serial
rating
plate
is
located
behind
the
left
filter
on
the
rear
wall
of
the
vent
hood.
Canopy
hood
location
should
be
away
from
strong
draft
areas,
such
as
windows,
doors
and
strong
heating
vents.
Cabinet
opening
dimensions
that
are
shown
must
be
used.
Given
dimensions
provide
minimum
clearance.
Grounded
electrical
outlet
is
required.
See
“
Electrical
Requirements
”
section.
The
canopy
hood
is
factory
set
for
venting
through
the
roof
or
wall.
For
non-vented
(recirculating)
Installation
see
“
For
Non-
vented
(recirculating)
Installations
Only
”
in
“
Connect
Vent
System
”
section.
Recirculation
Kit
Part
Number
W1
0349327
is
available
from
your
dealer
or
an
authorized
parts
distributor.
All
openings
in
ceiling
and
wall
where
canopy
hood
will
be
installed
must
be
sealed.
For
Mobile
Home
Installations
The
installation
of
this
range
hood
must
conform
to
the
Manufactured
Home
Construction
Safety
Standards,
Title
24
CFR,
Part
328
(formerly
the
Federal
Standard
for
Mobile
Home
Construction
and
Safety,
Title
24,
HUD,
Part
280)
or
when
such
standard
is
not
applicable,
the
standard
for
Manufactured
Home
Installation
1982
(Manufactured
Home
Sites,
Communities
and
Setups)
ANSI
A225.1/NFPA
501
A,
or
latest
edition,
or
with
local
codes.
*For
non-vented
(recirculating)
installations
"For
vented
installations
4