Performance Data Sheet
SmartWater Filtration System
GWF/ HWF Cartridge
This system has been tested according to NSF/ANS142/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter
Chlorine
T&O
Particulate**
USEPA
MCL
Influent
Challenge Concentration
2.0 mg/L + 10%
at least 10,000particles/mL
Effluent
Average Maximum
0.02 ppm 0.05 ppm
3,978 7,800
% Reduction
Average Minimum
98.90% 97.37%
98.00% 96.10%
Min. Required
Reduction
> 50%
>85%
Standard No, 53: Health Effects
Parameter Influent Effluent
Challenge Concentration Average Maximum Average
Turbidity 11 + 1 NTU*** 0.07 NTU 0.1 NTU 99.71%
Cysts Minimum 50,000 L 26 55 99.97%
Lead at pH 6.5 0.15 mg/L + 10% i ppb i ppb 99.37%
Lead at pH 8.5 0.15 mg/L + 10% 1.8 ppb 4.3 ppb 98.8%
Lindane 0.002 mg/L + 10% 0.00005ppm 0.00005ppm 91.93%
Atrazine 0.009 mg/L + 10% 0.002 ppm 0.003 ppm 76.19%
2,4-D 0.210 mg/L + 10% 0.042 ppm 0.090 ppm 84.89%
Asbestos 107to 10_fibers/L; 0.32 MFUml 1.2 MFUml 99.95%
fibers greater than
10 micrometers in length
USEPA
MCL
1 NTU***
99.95% Reduction
15 ppb
15 ppb
0.0002ppm
0.003 ppm
0.100 ppm
99%
% Reduction
Minimum
99.59%
99.95%
99.37%
97.13%
91.93%
64.28%
67.63%
99.82%
Min. Required
Reduction
0.5 NTU
> 99.95%
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.003 mg/L
0.07 mg/L
99%
Tested using a flow rate of O.5 gpm; pressure of 60 psig; pH of 7.5 +_0.5; temp. of EO° +_2.5°C
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity units
Operating Specifications
Capacity: certified for up to 300 gallons (1135 I)i up to six months for models without a replacement filter indicator lighL up to one
year for models with a replacement filter indicator light
Pressure requirement: 40-120 psi (3.8-8.2 bar), non-shock
Temperature: 33-100°F (0.6-38°C)
Flow rate: 0.5 gpm (1.9 Ipm)
General Installation/Operation/Maintenance Requirements
Flush new cartridge at full flow for 3 minutes to purge out trapped ain
Replace cartridge when flow becomes too slow.
Special Notices
Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
This drinking water system must be maintained according to manufacturer's instructions, including replacement of filter
cartridges.
Do not use with water that is microbiologicallg unsafe or of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cgsts.
The contaminants or other substances removed or reduced bg this water treatment system are not necessarily in your water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
Systems must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
System Tested and Certified bg NSF International against ANSI/NSF Standard 42 & 53 for the
reduction of:
Standard No. 42: Aesthetic Effects
Chemical Unit
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction, Class I
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead and Atrazine Reduction
Lindane and 2,4-D Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction
Manufactured for: General Electric Company, Louisville, KY 40225