DSO3000 SERIES
DIGITAL OSCILLOSCOPE
Simple Measurement
To acquire and display a signal, please do the steps as follows:
1. Connect signal to CH1 by using probe
2. Click the button on toolbar or “Acquire -> Auto Setup” on menu.
The DSO set the vertical, horizontal, and triggers controls at the best status automatical-
ly. Also, you can adjust the controls to meet your measurement to optimize the waveform
display.
To measure the frequency and “Vpp”, you can do these steps as follows:
1. Click the “Measure->Horizontal->Frequency” button, the frequency of the signal
display on the bottom of the waveform interface.
2. Click the “Measure->Vertical->Peak-to-Peak” button, the “Vpp” of the signal will also
display on the bottom of the waveform interface.
3. To clear the measurement on the waveform interface, click the “Measure->Clear
Measure” button.