Vevor FB3500-10A300 80 Gallon Air Compressor, 6.5hp 15.5scfm@90 Psi, 2-stage 145psi Oil Free Stationary Air Compressor Tank, 86db Ultra Quiet Compressor

User Manual - Page 10

For FB3500-10A300.

PDF File Manual, 12 pages, Read Online | Download pdf file

FB3500-10A300 photo
Loading ...
Loading ...
Loading ...
10
The upper drainage
valve does not
discharge water
line clogging
Check and exclude
abnormal sound
1. Fastener loose or damaged
2. piston ring with cylinder
excessive wear
3.foreign matter into the air
compressor
4.Large swing of the crank
1. Check and replace
2. Replace new
products
3. Check and exclude
4. Check and replace
Attention
1. In the process of work, ensure that there are no objects that can be
reached within the whole range of travel that can be moved.
2. The gas storage tank should be drained regularly, usually one to two days.
The sewage discharged from the gas storage tank shall be treated in
accordance with the local laws and regulations of the user.
3. Clean the silencer often.
4. When replacing electrical components, the power supply must be cut off.
5. When maintaining and cleaning the machine, the power supply must be cut
off.
6. For untrained personnel, use dental electric oil-free air compressor to avoid
wrong operation.
7. The maintenance of electric oil-free air compressor must be carried out by
trained professional maintenance personnel.
8. The elderly, children, the mentally disabled and the mentally ill must be
supervised by special persons to avoid the damage caused by their control of
the dental electric oil-free air compressor.
9. It is prohibited to use electric oil-free air compressors when it is known or
should be foreseen that electric oil-free air compressors may cause harm to
personnel.
10. After retiring the electric oil-free air compressor, the processing of
capacitance and electronic components should comply with the local laws and
regulations of the user.
11. After two months of installation and use, the connection bolts of the
electric oil-free air compressor must be checked. If they are loose, they must
be tightened immediately. Check it every six months after that.
12. Electric oil-free air compressor is strictly prohibited from filling any
lubricating oil.
Loading ...