Loading ...
Loading ...
Loading ...
4
GT45E ‘FAST FRI’ GAS FRYER (Single Tank - 20Ltr).
GT46E ‘FAST FRI’ GAS FRYER (Twin Tank - 13Ltr per Tank).
GT60E ‘FAST FRI’ GAS FRYER (Single Tank - 31Ltr).
- Australia:
- New Zealand:
- United Kingdom & EU (CE)
Category:
II
2H3P
(20. 37), II
2H3B/P
(20, 28-30),
Flue Type: A
1.
NOTE:
(
*
) Measure burner operating pressure at Lower Test Point (Out) on the gas control valve, with
both burners operating at 'High Flame' setting. Refer to ‘Gas Conversion and Specification’
Section for further details.
Input Rating (N.H.G.C.) 90 MJ/hr 90 MJ/hr
Supply Pressure 1.13 - 2.00 kPa 2.75 - 3.00 kPa
Burner Operating Pressure (*) 0.98 kPa 2.50 kPa
Gas Connection ¾” BSP Male
Input Rating (N.H.G.C.) 90 MJ/hr 90 MJ/hr
Supply Pressure 1.13 - 2.00 kPa 2.75 - 3.00 kPa
Burner Operating Pressure (*) 0.98 kPa 2.50 kPa
Gas Connection ¾” BSP Male
Heat Input (nett) 22.5 kW 22.5 kW 24.2 kW
Gas Rate 2.26 m
3
/hr 1.75 kg/hr 1.91 kg/hr
Supply Pressure 20 mbar 37 mbar 28-30 mbar
Burner Operating Pressure (*) 9.8 mbar 25 mbar
Gas Connection
3
/
4
” BSP Male
Loading ...