EN - 14
4. Connect the ground conductor (green wire) under the terminal B. Then connect the
neutral wire (white wire) to center of the terminal. Nuetral ground conductor of the dryer
should remain on the center terminal. Be sure that neutral ground conductor of dryer and
neutral wire of supply cord connected to center terminal together. Tighten all screws.
5. Connect remaining wires under the outer terminals of the block and tighten all screws.
After every connection is completed, tighten strain relief clamp in order to secure the
supply cord. Finally, cover up the box cover.
3.6. 3-Wire Power Supply Cord Connection
WARNING
•Before the connection, disconnect the power.
•Use UL listed 240V / 30A power supply cord.
Your dryer was equipped with strain relief. Use this strain relief in connection.
1. Remove the screw and terminal box cover.
2. Remove the clamp of the strain relief which has already attached on your machine.
Then pass the clamp through the supply cord and put the supply cord through the main
body of the strain relief. Be sure that wire insulation of the cord inside the strain relief.