Installation
*INSTALLATION*
33
Recirculation mode
The silencer needs to be positioned
between the exhaust connection and
the directional unit . Ensure there is
adequate space in the tower for fitting
it.
Electrical connection
The rangehood must only be connected
to a properly installed AC230V ~ 50Hz
earthed socket.
The electrical installation must be in
compliance with current local and
national safety regulations.
For extra safety, it is advisable to
protect the appliance with a suitable
residual current device (RCD) with a trip
current of 30mA.
Connection via a socket is
recommended as it facilitates servicing
of the appliance. The socket should be
easily accessible after the appliance
has been installed.
If the socket is no longer accessible
after installation, an additional means of
disconnection must be provided for all
poles which complies with national and
local safety regulations. Suitable means
of disconnection include switches with
an all-pole contact gap of at least
3mm.
These include isolator switches, fuses
and relays.
The relevant connection data can be
found on the data plate (see "Service").
Ensure that this data matches the
voltage and frequency of your
household mains supply.