Cleaning and care
21
Important information for the control
elements
If soiling is not removed promptly, it
could cause the control elements to
alter or discolor.
Remove any soiling immediately.
The surface of the control elements
can be damaged if they are cleaned
using stainless steel cleaning agents.
Do not use stainless steel cleaning
agents on the control elements.
Grease filters
Fire hazard!
Oversaturated grease filters are a fire
hazard.
Clean the grease filters at regular
intervals.
The re-usable metal grease filters in the
appliance remove solid particles
(grease, dust, etc.) from the kitchen
vapours, preventing soiling of the
rangehood.
The grease filters must be cleaned at
regular intervals.
Heavily soiled grease filters hinder air
extraction and will lead to increased
levels of soiling in the rangehood and
in the kitchen.
Grease filter cleaning intervals
Accumulated grease solidifies over a
longer period of time and makes
cleaning more difficult. The grease
filters should therefore be cleaned every
3 to 4 weeks.
Removing the grease filter
When handling the grease filter,
be careful not to drop it.
This can result in damage to the filter
and the cooktop below.
Make sure you hold the filter securely
at all times when handling it.
To take out the grease filter, release
the locking clip on the filter, lower the
filter approx. 45°, unhook it at the
back and remove it.