Renogy RBC10A2P-RE-US 24V 10A AC-to-DC LFP Portable Battery Charger

Quick Guide - Page 8

For RBC10A2P-RE-US.

PDF File Manual, 12 pages, Read Online | Download pdf file

RBC10A2P-RE-US photo
Loading ...
Loading ...
Loading ...
07
Troubleshooting
Over-temperature
Protection
Undervoltage
Protection
Short Circuit
Protection
Condition Steps to Take
1. When there is a short circuit between
the two poles of the ring terminals in the
battery charger, the Short Circuit
Protection will be triggered. The charger
stops working immediately, and the LED
indicator goes out.
1. When the internal temperature of the
AC charger is greater than 85(±5), the
charger's Over-temperature Protection
will be triggered.
1. When the battery voltage is between
13V and 15V, the Undervoltage
Protection of the charger will be triggered.
2. The 24V battery has almost reached its
end of lifespan when its voltage drops to
a range of 13V to 15V. Please contact the
battery manufacturer for further support.
2. After the Over-temperature Protection
is triggered, the indicator light of the
charger will go out and the charging
current of the charger will immediately
drop below 6A.
2. Disconnect the connecting wire of the
AC terminal immediately. When the short
circuit between the live wire and the
neutral wire is resolved, wait for 10
seconds, and then reconnect the AC
terminal wire, and the charger will restart.