PRESSURE WASHER Specications
WIRING DIAGRAM - SGP-403537E CAL
CAD
CELL
TIMER - 3 SEC
RELAY
COM
N.O.
YLW
BLK
RED
PHOTOCELL
+-
YLW
RED
RED
BLK
IGNITOR
12 VCD
WHT
PUR
FUEL SOLENOID
(SHUT-OFF VALVE)
12-24VDC
BURNER
MOTOR
12VCD
BLK
RED
BLK
WHT
BLK
RED
+
-
GROUND TO
BURNER HOUSING
xt9 WITH SCREW
MACHINE CONNECTION
B
C
A
+
1. APPLY 12V:
-BURNER MOTOR, STARTS FUEL FLOW
-FUEL SOLENOID, FUEL NOZZLE START TO ATOMIZE DIESEL
-TIMER DELAY, ACTIVATES THE IGNITOR
2. AFTER 3 SEC, TIMER RELAY SHUTS OFF THE IGNITOR (CAD
CELL WILL START THE IGNITOR AGAIN IF FLAME IS LOST)
3. REMOVE 12V
-BURNER MOTOR, STOPS FUEL FLOW
-FUEL SOLENOID, BYPASS THE FUEL
-TIMER DELAY, SHUTS OFF THE IGNITOR
4. SEQUENCE STARTS AGAIN WHEN 12V APPLIED