Karcher 1.110-059.0 SGP Shark Series High Pressure Cleaner

Operating instructions - Page 49

For 1.110-059.0. Series: Shark Series
Also, The document are for others Karcher models: SGP-302517, 1.110-054.0, SGP-303037, 1.110-055.0, SGP-353037, 1.110-068.0, 1.110-056.0, SGP-353037E, 1.110-069.0, 1.110-057.0, SGP-403537E, 1.110-070.0, 1.110-078.0, 1.110-083.0, SGP-403537E CAL

PDF File Manual, 52 pages, Read Online | Download pdf file

1.110-059.0 photo
Loading ...
Loading ...
Loading ...
Manual Karcher SGP 9.801-192.0 - H
49
PRESSURE WASHER Specications
CAD
CELL
TIMER - 3 SEC
RELAY
COM
N.O.
YLW
BLK
RED
PHOTOCELL
+-
YLW
RED
RED
BLK
IGNITOR
12 VCD
WHT
PUR
FUEL SOLENOID
(SHUT-OFF VALVE)
12-24VDC
BURNER
MOTOR
12VCD
BLK
RED
RED
BLK
62411-052
12 GA FROM NUT
13743
16 GA FROM NUT
WHT
BLK
RED
62411-053
12 GA FROM NUT
+
-
W
O
GROUND TO
BURNER HOUSING
xt9 WITH SCREW
MACHINE CONNECTION
B
C
A
87
RELAY
87A
85
30
R
BURNER
LAMP
86
FLOW
SW
IT
CH
21P1
-
12VDC
HOUR METER
CAPACITOR
R
CONTROL PANEL
+
BREAKER
CIRCUIT
Y
GR
R
ACPOS
YEL
AC
REDYEL
R
EG
ULATOR/RECITIFIER
VOL
TAGE
NEG
BLK
GR
Y
ENGINE
GR
Y
GR
Y
C
B
A
30
RELAY
87A
86
87
85
ALL WIRES BLACK UNLESS NOTED
W - WHITE
G - GREEN
R - RED
Y - YELLOW
O - ORANGE
BL - BLUE
GR - GREY
1. APPLIED 12V ENERGIZES
-BURNER MOTOR WICH STARTS FUEL FLOW
-SHUT OFF VALVE WICH ALLOWS FUEL TO FLOW OUT OF
PUMP
-3 SEC, TIMER ENERGIZES THE IGNITOR TO IGNITE
FUEL
2. AFTER 3 SEC, TIMER DE-ENERGIZES THE IGNITOR
(RESISTOR JUMPER)
ON PHOTOCELL ELEIMATES RE-ENERGIZING IGNITOR IF
FLAME IS LOST
3. AFTER 12V HAVE BEEN REMOVED
-BURNER MOTOR IS DE-ENERGIZED WICH STOPS FUEL
FLOW
-SHUT OFF VALVE IS DE-ENERGIZED WICH STOPS FUEL
FLOW OUT OF PUMP
-3 SEC TIMER IS DE-ENERGIZED
4. SEQUENCE STARS AGAIN WHEN 12V APPLIED