*Settingreversingvalveisnecessaryforheatpumpusersonly.Pleaserefertothechartinsection 3.3 for your old
thermostat’swiring.
On your OLD thermostat
•ifyouhadawireconnectedto“O”terminal,setreversingvalve(menu#20)valveas“O”atthisstep.
•ifyouhadawireconnectedto“B”terminal(andatthesametime,nowirewasconnectedto“O”),setreversing
valveas“B”atthisstep
•ifyouhadawireconnectedto“O/B”terminal,pleasecallCustomerSupportat877.654.9394.
User Menu #
(Hold Menu 8 Seconds)
Description
Default Setting
(ashing icons)
Settings
(Press or )
32 CR
Aux Cycle Rate: how often the
auxiliary heat will turn on
MEd
SLO – slow
MEd – medium
FAS – fast
35 CR
Cool Cycle Rate: how often the
cooling will turn on
MEd
SLO – slow
MEd – medium
FAS – fast
50 CL
Compressor Lockout:
protects the compressor from short
cycling
OFF
On – 5 minute delay
OFF – no delay
65
Max Heat Limit: maximum set
point for heat mode
99 47 to 99
66
Minimum Cool Limit: minimum set
point for cool mode
45 45 to 97