The normal operation status of the stick logger, when router connected to the network
normally:
1.Connection to the server succeeded: NET light keeps on after the logger powered on.
2.Logger running normally: READY light flashes.
3.Connection to the inverter succeeded: COM light keeps on.
Type 1
Step1: Assemble logger to the inverter
communication interface as shown in the
diagram.
Logger Status
Check Indicator light
Type 2
Step1: Assemble logger to the inverter
communication interface as shown in the
diagram.
Warning:
Please do not hold the logger body to rotate while
install or remove the logger.
1. Stick Logger Installation
Implication Lights Status Description(All lights are single green lights.)
Communication
with router
Communication
with inverter
Logger running
status
1.Light off: Connection to the router failed.
2.On 1s/Off 1s(Slow flash): Connection to the router succeeded.
3.Light keeps on: Connection to the server succeeded.
4.On 100ms/Off 100ms(Fast flash): Distributing network fast.
1.Light keeps on: Logger connected to the inverter.
2.Light off: Connection to the inverter failed.
3.On 1s/Off 1s(Slow flash): Communicating with inverter.
1.Light off: Running abnormally.
2.On 1s/Off 1s (Slow flash): Running normally.
3.On 100ms/Off 100ms(Fast flash): Restore factory settings.
NET
COM
READY