NVR and Camera Configuration Guide
AcuSense NVR and Camera Configuration Guide 071219NA 19
Figure 22, View Alarm Information on iVMS-4200 (Vehicle)
The NVR alarm upload via iVMS-4200 is the same as for a network camera. The Target Type shown on
the iVMS-4200 is consistent with the Detection Type set on the configuration interface. Unchecked
categories will be filtered out and will not be displayed on the iVMS-4200.
Known Issue
When adding network cameras to the NVR, the NVR will issue a 24-hour arming schedule to the camera
by default. After the camera is connected, configuring an arming schedule on the NVR will affect only
whether the alarm is reported and displayed on this NVR, but the camera setting time will not change. If
other terminals access the camera, the alarm will still be received.
Product List
Scheme Camera NVR Client
AcuSense NVRs and
AcuSense Cameras
DS-2CD2/3xx6 AcuSense NVR V2.6.7.3 build 20180225
Installation Requirements
The proposal altitude of installation distance is 3 to 5 meters, equipment bow angle is
approximately 10°, specific adjustments are according to the environment.
The maximum monitoring distance depends on the lens’ focal length. The table of the maximum
monitoring distance for the specific focal length is as follows:
Lens (mm)
Recommended Maximum Monitoring Distance
2.8 mm
10 m
4 mm
15 m
6 mm
22 m
The monitoring area cannot be covered by nearby objects. Do not shoot backlight at the
installation position, which will affect the image effect. The following shows a perimeter
environment installation: