Celestron 44130 Labs CM2000CF Compound Microscope

User Manual

For 44130.

PDF File Manual, 8 pages, Read Online | Download pdf file

44130 photo
English
Congratulations on your Celestron Labs
microscope purchase. Your new Celestron
Labs microscope is a precision optical
instrument, made of the highest quality
materials to ensure durability and long life. It
is designed to give you a lifetime of pleasure
with a minimal amount of maintenance.
Before attempting to use your Celestron
Labs microscope, please read through
these instructions thoroughly to familiarize
yourself with the parts and functions of the
microscope to maximize your enjoyment and
usage. Refer to the microscope diagrams to
locate the parts discussed in the manual.
This CM2000CF microscope provides powers
from 40x up to 2000x. It is ideally suited
for examining specimen slides of yeasts
and molds, cultures, plant and animal parts,
fibers, bacteria, etc.
IN THE BOX
- Microscope CM2000CF
- Four Objective Lenses -4x, 10x, 40x (spring
loaded), 100x (spring loaded)
- Two WF Eyepieces- 10x with Pointer, 20x
- 10 Prepared Slides
- 3 Colored Filters- Blue, Yellow, Red
PARTS
1. Eyepiece
2. Eyepiece Tube
3. Nosepiece
4. Stage Holder Clamp
5. Iris Diaphragm
6. Mechanical Stage
7. Abbe Condenser
8. Illuminator
9. Power Switch
10. Head
11. Arm
12. Objective Lens
13. Coarse Focus Knob
14. Stage Control Knobs
15. Fine Focus Knob
16. Illuminator Adjustment
17. Base
SPECIFICATIONS
STAGE: Mechanical Stage - 4.3 in x 4.9 in
(110 mm x 125 mm)
HEAD: 360° rotatable monocular with
45° incline
MAGNIFICATION RANGE: 40x to 2000x
FOCUSER: Coarse and fine focus knobs
OBJECTIVES: Achromatic 4x, 10x, 40x, 100x
EYEPIECES: WF 10x with pointer, WF 20x
NOSEPIECE: Quadruple with click stop
ILLUMINATOR: Halogen, adjustable
CONDENSER: Abbe N.A. 1.25 with Iris
Adjustment
DIAPHRAGM: Iris
DIMENSIONS: 5.5 in x 7.25 in x 15.12 in
(140 mm x 184 mm x
384 mm)
WEIGHT: 6 lbs- 6 oz. / 2.9 kg
MAGNIFICATION TABLE
Use the following table to determine
magnification using your microscope’s
different eyepiece/objective lens
combinations.
OBJECTIVE LENS:
4x 10x 40x 100x
WF 10X EYEPIECE:
40x 100x 400x 1000x
WF 20X EYEPIECE
80x 200x 800x 2000x
SETTING UP YOUR
MICROSCOPE
1. Remove the Styrofoam container from the
carton.
2. Carefully remove the microscope and
accessories from container and set them
on a table, desk, or other flat surface.
3. Remove bag covering from microscope.
4. Remove cap from eyepiece tube (2).
5. Remove the eyepieces from plastic bags.
6. Insert the wide field 10x eyepiece into the
eyepiece tube (2).
7. Remove the four objective lenses (12) from
their containers. Unscrew the container lids
from the threaded portion of the objective
lenses.
8. Using caution, thread the end of the 4x
objective lens (color coded red) into one of
the holes on the nosepiece (3) thoroughly
until its finger tight. It may be necessary
to lower the mechanical stage (6) by
turning the coarse focus knob (13).
9. Turn the nosepiece (3) to the next opening
and thread each of the remaining objective
lenses into the remaining holes.
10. Insert the plug end of the power cord into
the proper power source.
MICROSCOPE OPERATION
Before viewing specimens, please read these
sections thoroughly regarding focusing,
changing power (magnification), using the
stage and adjusting illumination.
ROTATING HEAD
The head (10) of your microscope can be
rotated 360 degrees so you can view from
any position. Simply move the head (10) to
the desired location.
CM2000CF
Model # 44130
1
2
10
11
12
14
17
16
15
13
3
4
5
6
7
8
9
Loading ...
Loading ...
Loading ...

Other documents for Celestron 44130

The following documents are available:
User Manual Photos

Specifications

See other models: 44129 44128 44360 44320 44121