MINIMUM INSTALLATION SPACING
18"
"1"'-'_
olo
**48 sq, in.
minimum"
ventilation
area
,D
h **24 sq, in.
minimum"
ventilation
area
2T'- ..---1" ''
FrontView SideView FrontView
(DoorNotShown) (DoorShown) (DoorWithVent)
3"
3"
;F
* Additional clearances for wall, doorandfloor moldings may be required. 0" clearance
is acceptablebutnotrecommended.
** Openingisminimum tor closet door.Loavered doorwith equivalent air
openings is acceptable.
*** Additional spaceis neededwhen externalexhaustelbow isused. Canbe O"clearance
when houseexhaustingislined up directlywith dryer exhaust.
• In the above illustration, the installation
spacing is in inches and is the minimum
allowable.
• Additional spacing should be considered
for ease of installation and servicing.
• If closet door is installed, the minimum air
openings in top and bottom are required.
Louvered doors with equivalent air open-
ings in top and bottom are acceptable.
• All installations must be exhausted
outside. Use at least the minimum
dimensions indicated.
I2