2.1 DC voltage
Range
(excluding maximum value)
Resolution
0-10V
10-100V
100-1000V
1000V
0.001V
0.01V
0.1V
1V
Accuracy
±(0.8% reading + 3 digits)
±(0.8% reading + 3 digits)
±(0.8% reading + 3 digits)
±(1.2% reading + 3 digits)
Maximum input voltage: 1000V DC RMS
Minimum measurement voltage: 0.75VDC
Press the SEL button to switch the auto range mode in the smart mode
Maximum input voltage: 1000V DC RMS
Minimum measurement voltage: 0.75VDC
Frequency response: 50HZ-1KHZ true RMS
Press the SEL button to switch the auto range mode in the smart mode
Accuracy
±(0.8% reading + 3 digits)
±(0.8% reading + 3 digits)
±(0.8% reading + 3 digits)
±(1.2% reading + 3 digits)
2.2 AC voltage
Range
(excluding maximum value)
Resolution
0-10V
10-100V
100-1000V
1000V
0.001V
0.01V
0.1V
1V