Users Manual
II. Transportation and Placement
Transportation
1. Don’t slant it over more than 45°, while moving it.
2. The cooler needs to stand upright for 4 hours before it is powered on, while the product is
transported upside down.
Choosing the installation location
1. The unit is for indoor application only.
2. Due to the fact that the unit has a glass door, its performance is highly influenced by environmental
conditions. To minimize the environmental effects on the unit’s performance, the following are
recommended:
The unit is not to be placed near any kind of heat source
The unit is not to be placed near or inside air streams produced by ventilation fans, open doors
and/ or windows
The unit is not to be situated under a roof-mounted ventilation system.
The unit should have sufficient space to ‘breathe’ (always use the rear space to ensure minimum
clearance).
Test room
climate class
Dry bulb
temperature
(C)
Relative
Humidity (%)
Dew point (⁰C)
Water vapor mass
in dry air (g/kg)
3
25
60
16.7
12.0
4
30
55
20.0
14.8
5
40
40
23.9
18.8
NOTE: the water vapor mass in dry air is one of the main points influencing the
performance and the energy consumption of the coolers. Therefore, the order of the
climate class in the table is based on the water vapor mass column.
Warning: Risk of fire / flammable materials