Broan E64E30SSLC 30-Inch External Blower Stainless Steel Range Hood Shell

Installation Instructions - Page 5

For E64E30SSLC. Series: ELITE E64000 SERIES

PDF File Manual, 16 pages, Read Online | Download pdf file

E64E30SSLC photo
Loading ...
Loading ...
Loading ...
5
Hood
3¼” x 10” duct
or 7” or 8” round duct
Roof cap
Wall
cap
HH0085A
24” minimum above
cooking surface
(30” for gas range)
3¼” x 10” to 7” or
3¼” x 10” to 8” transition
(if using round duct)
1. SELECT BLOWER OPTION
The Broan Elite E64000LC Series range hood includes many configurations: hoods with single or double internal blowers (included with
the hoods), or hoods using external blowers. For hoods using external blowers, the Broan Elite E64000LC Series must be installed with
in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or 336 only. Other blowers cannot be
substituted. (Blowers sold separately).
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1, 2, 3, 4, 9 and up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7", 8" or 10" round ducts, use a
transition (internal blower(s) only). Use 2" metal foil duct tape to seal duct joints.
We recommend to install the hood at a minimum distance of 24” from an electric range and at 30” from a gas range.
Distances over 30" are at the installer and users discretion.
Hood
10” round duct
Roof cap
Wall
cap
4½” x 18½” to 10”
transition
HH0086A
24” minimum above
cooking surface
(30” for gas range)
HH0087A
Hood
10” round duct
Exterior blower
24” minimum above
cooking surface
(30” for gas range)
In-line blower
10” round duct (except
HLB3, 8” round duct)
HH0092A
24” minimum
above cooking
surface
(30” for gas range)
Roof cap
Wall
cap
Hood
SINGLE INTERNAL BLOWER
TYPICAL DUCTWORK
DOUBLE INTERNAL BLOWERS
TYPICAL DUCTWORK
MODEL 331H, 332H, 335 OR 336
EXTERIOR BLOWER TYPICAL DUCTWORK
MODEL HLB3, HLB6, HLB9 OR HLB11
IN-LINE BLOWER TYPICAL DUCTWORK
Loading ...
Loading ...
Loading ...