Zibro LC 150 The Zibro Laser Clean heater

OPERATING MANUAL - Page 22

For LC 150.

PDF File Manual, 168 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
4
10
I THE INFORMATION DISPLAY
The information display not only serves as an indicator of the (set) time and
temperature (
Sections C, D, and G), it also indicates any malfunctioning of the
heater. The code on the information display tells you what is the matter:
CODE INFORMATION WHAT TO DO
e - 0 Temperature within the heater too high. Cool-down and re-ignite.
f - 0 Power interrupted. Re-ignite the heater.
e - 1 Faulty thermostat. Contact your dealer.
f - 1 Faulty burner thermistor. Contact your dealer.
e - 2 Starting problems. Contact your dealer.
e - 23
Re-ignite the heater immediately after
extinguishing.
Wait for approx. 30 sec.
and re-ignite after inserting
the plug again.
e - 5 Tipping-over protection. Re-ignite the heater.
e - 6 Poor burning. Contact your dealer.
e - 7 Room temperature If necessary,
above 32°C. re-ignite the heater.
e - 8 Defective booster. Contact your dealer.
e - 8 1 Abnormal frequency. Insert the plug into the wall-socket again.
Contact your dealer.
e - 9 Air filter dirty; or Clean filter.
Fuel pump dirty. Contact your dealer.
The heater has been in operation
continuously for a period of 50 hours
and has turned itself off automatically. Switch the heater back on.
-- : --
+
Out of fuel. Refill removable tank.
-- : --
+
Too little ventilation. Ventilate better.
Always฀contact฀your฀dealer฀for฀any฀malfunctioning฀not฀listed฀above฀and/or฀when฀
the error keeps occuring after taking the corrective measure as described above.
AUTOMATIC DEACTIVATION
This heater is fitted with a safety system that ensures that it switches off
automatically after 50 hours continuous operation. The following will then appear
in the display:
. If desired, you can switch the heater on again by pressing
the
button
(see Section F).
AUTOMATIC CLEANING MODE
When the heater has been burning continuously for two hours at its highest
setting, the burner will automatically start an autoclean procedure. The display
will show the autocleaningcode cl:05 running back to cl:01. The procedure takes 5
minutes, during which the heater will burn at its lowest setting, while the burner
autocleans. When the burner is clean again, the heater will automatically switch
back to the highest setting again.
In case of any
malfunctioning the
information display will
tell you what is the
matter.
Loading ...
Loading ...
Loading ...