Measure plug gap
Measure the plug gap with a gauge. The gap should be 0.7-0.8
mm (0.028-0.031 in).
4.
Clean and re-gap
Replace spark plug
Replace spark plug cap
If you are re-using the spark plug, use a wire brush to clean
any dirt from around the spark plug base and then re-gap the
spark plug.
Screw the spark plug back into its place on the generator
using the spark plug wrench.
Replace the spark plug cap.
5.
6.
7.