11
IMPORTANT: Never use abrasive cleaners as these are likely to spoil the appearance of your appliance.
Instead, clean your appliance with a slightly moist rag and the brush provided with the device.
If you have any questions, please see the ROWENTA international guarantee card enclosed with this
product, where you will find the Consumer Service contact details.
CLEANER AND DESCALER PROVIDED WITH THE APPLIANCE
INSTRUCTIONS FOR USE:
1- Turn off the unit and remove the water tank.
2- Add the powder from 2 bags to 0.6 liters of hot water in a container.
Stir until the powder has completely dissolved.
3- Fill the water base with this solution and wait for 1 hour to take effect.
4- Empty and remove the scale using the brush provided with the product.
5- Rinse out the whole of the compartment with fresh tap water
(Important, make sure that no water gets into the blower opening).
6- Your appliance is now ready to be used again.
WARNING:
keep out of reach of children -
harmful if ingested - Irritating to eyes and skin.
FIRST AID:
EYE CONTACT - Flush immediately with water for at least
15 minutes and seek medical advice.
SKIN CONTACT - wash immediately with soap and water.
INGESTION - DRINK ENOUGH WATER TO SPIT ; MAY CAUSE UPSET STOMACH -
GET MEDICAL ADVICE/ATTENTION.
INGREDIENTS:
CITRIC ACID >99%
You can also use the ANTICALC KIT of KRUPS, sold as accessory, F054 (F0540051).
Please notice, only 20 grams of the powder are necessary for the descaling operation of your device
STORAGE
When the appliance is not in use, it should be stored in a dry place.
Make sure to empty the tank, clean and dry the appliance before storing it.
IN THE EVENT OF A PROBLEM
Never dismantle your appliance yourself. An incorrectly repaired appliance can be a danger to the user.
Before contacting an approved Service Centre from our network, make sure that the appliance is in the
normal operating position and the air intake and outlet grills are totally unobstructed.
P roblem Possible Cause What to do
The appliance does
not work when swit-
ched on
The target humidity is reached.
Increase the target humidity in CONTROL
MODE or select CONTINUOUS MODE.
The water level indicator is
blinking.
Refill the water tank.
The water tank isn’t well posi-
tioned.
Check the positioning of the tank on the
base.
The appliance isn’t on a flat
surface.
Check the positioning of the appliance (tilt).
The water level required has
not yet reached the vaporiza-
tion compartment.
Wait at least 20 secs.
The RH% of the room is over
90%.
Wait till the RH% of the room gets below
80%.
The humidification ca-
pacity is too low
There is natural or artificial air
replacement in the room which
interfere the increase of RH%.
Check if doors and windows are closed.
Check if there is no air conditioning working
in the room.
The air inlet grids and nozzle
could be blocked.
Remove any blocking items from the grids
and the nozzle.
There is too much scale in the
water basin or on the piezo
part.
Clean the water base according to Mainte-
nance Instructions.
The Humidity selected rate is
too low.
Increase Vaporization Speed in CONTROL
MODE.
Increase Humidity setting in CONTROL
MODE.
The ambient humidity
is too high
The appliance is working in
CONTINUOUS MODE.
Change the mode.
The humidity target is too high. Select a lower RH% target.
There is condensation
in the room
The room temperature is too
low.
Heat the room up.
EN