USE, INSTALLATION AND MAINTENANCE INSTRUCTIONS - Page 8

For CG705WXFFC. Also, The document are for others Blanco models: CG302FFX, CG604WXC, CG604WXFFC, CG604XP, CG604XFFP, CG604WXP, CG604WXFFP, CG705WXC

Loading ...
Loading ...
Loading ...
INSTALLATION
8
5) GAS CONNECTION
The gas connection is located in the rear and on the
underside of the appliance 118 mm (for EH/60) from
the right hand side.
There are two ways to carry out the connection to
the main gas line:
A. the hotplate can be connected with rigid pipe as
specified in AS5601 table 3.1.
B. The hotplate can be connected with a Flexible
Hose, which complies with AS/ANZ 1869 (AGA
Approved), 10 mm ID, class B or D, no more than
1.2 m long and in accordance with AS5601.
Ensure that the Hose does not contact the hot
surfaces of the hotplate, oven, dishwasher or other
appliance that may be installed underneath or next
to the hotplate. The Hose should not be subjected
to abrasion, kinking or permanent deformation and
should be able to be inspected along its entire
length.
Unions compatible with the hose fittings must be
used and connections tested for gas leaks.
Ensure the supply connection point is accessible
with the appliance installed.
Warning: ensure that the hose assembly is
restrained from accidental contact with the flue or
flue outlet of an underbench oven.
Natural Gas
Natural Gas installations require the connection of
a gas regulator at the appliance. This regulator is
supplied with the appliance on purchase.
Assemble the regulator (noting the gas flow
direction) and transition pieces (supplied with the
appliance), in accordance with figure 10.
The transition piece on the supply side of the
regulator must be provided by the installer.
Liquified Petroleum Gas
In a Propane installation the gas regulation is
made at the gas cylinder and regulation at the
appliance is not required. To connect supply to the
appliance use transition pieces as shown in
figure 11. These pieces are supplied with the
appliance on purchase.
WARNING:
THE BURNER FLAME MUST BE ADJUSTED BY
THE INSTALLER.
FAULTY INSTALLATION WILL NOT BE
COVERED UNDER WARRANTY.
THE APPLIANCE IS FACTORY SET FOR
NATURAL GAS. THE TEST POINT PRESSURE
SHOULD BE ADJUSTED TO 1.00kPa WITH THE
WOK BURNER OPERATING AT MAXIMUM.
FIG. 10 FIG. 11
Loading ...
Loading ...
Loading ...