Loading ...
Loading ...
Loading ...
en Troubleshooting
40
Fault Cause and troubleshooting
The programme does
not start.
2.
→"Starting the programme", Page27.
The length of the pro-
gramme changes dur-
ing the drying cycle.
The programme operation is optimised electronically.
This may change the programme duration.
▶ Not a fault – no action required.
Pumping noise. Condensation pump active.
▶ Not a fault – normal operating noise.
Buzzing noise. Compressor ventilation active.
▶ Not a fault – normal operating noise.
The drying time is too
long.
The base unit's filter is soiled.
▶
→"Cleaning the filter system on the base unit",
Page30
Fluff filter is soiled.
▶
→"Cleaning the fluff filter", Page28
The ambient temperature is greater than 30 °C.
▶ Ensure that the ambient temperature is below 30
°C.
The ambient temperature is lower than 15 °C.
▶ Ensure that the ambient temperature is above 15
°C.
Insufficient air circulation at the appliance's installation
location.
▶ Ventilate the appliance's installation location.
The appliance's ventilation opening is blocked.
▶ Ensure that the ventilation opening of the appliance
is kept clear.
Heat exchanger is soiled.
1. Opening the base unit.
→"Opening the base unit", Page34.
2. Cleaning the heat exchanger.
→"Cleaning the base unit", Page35.
3. Closing the base unit.
→"Closing the base unit", Page36.
Water is leaking from
the appliance.
Appliance is not correctly aligned.
▶
→"Aligning the appliance", Page16
The seal for the heat exchanger cover is dirty.
▶ Clean the seal for the heat exchanger cover.
→"Cleaning the filter system on the base unit",
Page30
Loading ...
Loading ...
Loading ...