122
3
Notes on continuous flash operation (in close-up flash operation (using cords))
To prevent the SB-R200 from overheating, allow the SB-R200 to cool down for at
least 10 minutes after the maximum number of continuous firings have been
performed as shown in the table below.
Max. number of continuous firings
Synchronization during continuous flash operation
It is possible to take up to the number of frames during continuous operation as
shown in the table below.
SB-R200’s maximum number of frames during continuous flash
operation (at six frames per sec.)
Flash mode Max. number of continuous
firings (at 6 frames/sec.)
TTL auto flash
15
Manual flash (Flash output level: M1/1, M1/2)
Manual flash (Flash output level: M1/4 to M1/64) 30
Flash output level
1/8 1/161/321/64
Up to 4 Up to 8 Up to 16 Up to 30
CAUTION
Do not exceed the maximum number of continuous
firings, as this may cause the flash head to overheat
and can result in burns and damage to the flash panel
and body.
CAUTION
Be careful when replacing batteries after continuous
flash use, because batteries may generate heat during
continuous flash photography.