7
I. Specications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certication marks, see the nameplate.
We reserve the right to make changes in specications and design without prior notice.
1. F-1501M_J(-C)(-SC)
Single Phase
Model Number F-1501MAJ(-C)(-SC) F-1501MWJ(-C)(-SC) F-1501MRJ(-C)(-SC)
AC Supply Voltage 208-230/60/1 (3 wire with
neutral)
208-230/60/1 (3 wire with
neutral)
208-230/60/1 (3 wire with
neutral)
Compressor 208-230V 9.3RLA 56LRA 208-230V 9.3RLA 56LRA 208-230V 9.3RLA 56LRA
Gear Motor 115V 5.6 FLA 400W 115V 5.6 FLA 400W 115V 5.6 FLA 400W
Fan Motor 115V 1.0 FLA 1/15HP Cabinet: 115V 0.51 FLA 8W Cabinet: 115V 0.51 FLA 8W
Remote: 115V 3A MAX
Other 115V 0.03A 115V 0.03A 115V 0.03A
Maximum Fuse Size 20 AMPS 20 AMPS 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS 20 AMPS 20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS 20 AMPS 20 AMPS
Minimum Circuit
Ampacity
20 AMPS 20 AMPS 20 AMPS
Design Pressure HI-467PSI LO-250PSI HI-427PSI LO-250PSI HI-467PSI LO-250PSI
Refrigerant 404A 2 LB. 5 OZ. 404A 1 LB 4.5 OZ. 404A
Total Refrigerant Charge
with Hoshizaki Remote
Condenser Unit URC-14F:
9LB. 9 OZ.
2. F-2001M_J(-C), F-2001MRJ-SC
Single Phase
Model Number F-2001MWJ(-C) F-2001MRJ(-C)(-SC) F-2001MLJ
AC Supply Voltage 208-230/60/1 208-230/60/1 115/60/1
Compressor 240V 10.8RLA 96LRA 240V 10.8RLA 96LRA – – –
Gear Motor 120V 5.6 FLA 400W 120V 5.6 FLA 400W 120V 5.6 FLA 400W
Cabinet Fan Motor 115V 0.51 FLA 8W 115V 0.51 FLA 8W 115 0.51 FLA 8W
Remote Fan Motor – – – 120V 3A MAX
Other 120V 0.03A 120V 0.03A 120V 0.3A
Maximum Fuse Size 30 AMPS 30 AMPS 15 AMPS
Max. HACR Breaker
(USA Only)
30 AMPS 30 AMPS 15 AMPS
Max. Circuit Breaker
(Canada Only)
30 AMPS 30 AMPS 15 AMPS
Minimum Circuit
Ampacity
30 AMPS 30 AMPS 15 AMPS
Design Pressure HI-467PSI
LO-290PSI
HI-467PSI
LO-290PSI
HI-467PSI
LO-290PSI
Refrigerant 404A 2 LB. 404A
Total Refrigerant Charge
with Hoshizaki Remote
Condenser Unit
URC-22F: 15LB. 14 OZ.
Use only with 404A,
407A, or 407F.
Factory Holding
Charge 15PSI Nitrogen
Loading ...