PERFORMANCE DATA SHEET
Base Grille Water Filtration System
Model TIKB1/TIRFKB1 Capacity 100 Gallons (379 Liters)
System tested and certified by NSF Internat!onal against NSF/ANSI Standard 42 for the reduction of
Chlorine Taste and Odor, Particulate Class I ; and against NSF/ANSI Standard 53 for the reduction of
Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane,
Tetrach oroethy ene, Endr n, A ach or, Ch orobenzene, Ethy benzene, TTHM, MTBE and VOC.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
Aesthetic Effects
Chlorine Taste/Odor
Particulate Class I*
Contaminant
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
O-Dichlorobenzene
Toxaphene
Atrazine
Asbestos
Live Cysts _
Turbidity
Alachlor
Endrin
Ethylbenzene
Lindane
Chlorobenzene
Tetrachloroethylene
TTHM
MTBE
VOC
NSF Reduction Average
Requirements Influent
50% reduction 2.0 mg/L
85% reduction 3533333#/mL
NSF Reduction Average
Requirements Influent
0.010 mg/L 150 ug/L
0.010 mg/L 157 ug/L
0.002 mg/L 0.0058 mg/L
0.002 mg/L 0.0057 mg/L
0.005 mg/L 15 ug/L
0.6 mg/L 1750 ug/L
0.003 mg/L 15 ug/L
0.003 mg/L 10 ug/L
99% 101 MFL
>99.95% 120,000/L
0.5 NTU 11.4 NTU
0.002 mg/L 41.3 ug/L
0.002 mg/L 5.9 ug/L
0.7 mg/L 1867 ug/L
0.002 mg/L 1.9 ug/L
0.6 mg/L 2.0 ug/L
0.005 mg/L 14.2 ug/L
0.080 mg/L 465 ug/L
0.005 mg/L 14 ug/L
0.015 mg/L 0.3520 mg/L
Influent Challenge
Concentration
2.0 mg/L + 10%
At east 10,000 part c es/mL
Influent Challenge
Concentration
0.15 mg/L+ 10%
0.15 mg/L_+ 10%
0.006 mg/L + 10%
0.006 mg/L _+10%
0.015 mg/L_+ 10%
1.8 _+10%
0.015 _+10%
0.009 mg/L _+10%
107to 108fibers/L _
50,000/L min.
11 _+1 NTU
0.04 _+10%
0.006 + 10%
2.1 _+10%
0.002 _+10%
2.0 _+10%
0.015 _+10%
0.45 _+20%
0.015 _+20%
0.300 _+10%
Maximum Average
Effluent Effluent
0.08 mg/L ** 2.0 mg/L
22000 #/mL 11567 #/mL
Maximum
Effluent
1.0 ug/L
2.0 ug/L
0.0002 mg/L
0.0002 mg/L
0.5 ug/L
1.0 ug/L
1.0 ug/L
2 ug/L
0.17 MFL
8/U
0.41 NTU
0.2 ug/L
0.5 ug/L
0.70 ug/L
0.02 ug/L
0.0005 ug/L
0.5 ug/L
1.0 ug/L
0.70 ug/L
0.0060 mg/L
Average
Effluent
1 ug/L
1.08 ug/L
0.0002 mg/L
0.0002 mg/L
0.5 ug/L
1.0 ug/L
1.0 ug/L
2 ug/L
0.17 MFL
1/ U
0.24 NTU
0.2 ug/L
0.3 ug/L
0.0588 ug/L
0.02 ug/L
0.0005 ug/L
0.5 ug/L
0.5 ug/L
0.52 ug/L
0.0008 mg/L
Minimum %
Reduction
95.93
99.38
Minimum %
Reduction
99.33
98.72
96.53
96.5
96.67
99.94
93.33
80.8
99.83
99.99
96.4
99.52
91.5
99.96
98.93
99.98
96.47
99.78
94.94
98.4
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 100 gallons (379 liters).
It is essential that operational, maintenance, and filter The product is for cold water use only.
Average %
Reduction
97.36
99.67
Average %
Reduction
99.33
99.31
96.53
96.5
96.67
99.94
93.33
80.8
99.83
>99.99
97.89
99.52
95.47
100
98.93
99.98
96.47
99.88
96.27
99.78
replacement requirements be carried out for the product to
perform as advertised.
Model TIKBI" The filter monitor system measures the amount of
water that passes through the filter and alerts you to replace the
filter.
Style 1 - When the filter indicator reads 10%, order a new filter.
When the indicator reads 0%, it is recommended that you
replace the filter.
Style 2 - When the filter indicator changes from green to yellow,
order a new filter. When the indicator changes from yellow to red,
it is recommended that you replace the filter.
Style 3 - When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter indicator
reads "REPLACE," it is recommended that you replace the filter.
Use replacement cartridge T1 RFKB1, part #9030.
2008 suggested retail price of $59.99 U.S.A./S71.99 Canada.
Prices are subject to change without notice.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Refer to the "Warranty" section for the Manufacturer's name,
address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate 0.5 gpm (1.9 L/min) @ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
ttFibers greater than 10 um in length
€Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.