18
Gas Conversion and Specifications
Static Oven
1. Carry out the following:-
 Remove lower lintel at front of oven.
 Open oven door and remove sole plate(s).
 Remove main burner.
 Remove thermocouple and piezo igniter from
mounting bracket. (For access purposes).
 Disconnect pilot supply tube from pilot burner
to access pilot injector.
2. With Main Burner removed, ensure aeration gap is adjusted for
type of gas being used as shown in ‘Gas Specifications Tables’ at
end of this section.
3. Remove pilot and main injectors and replace with correct size
injectors as shown in ‘Gas Specifications Tables’ at end of this
section.
4. Refit the following:-
 Re-connect pilot supply tube to pilot burner.
 Re-connect piezo igniter and thermocouple to mounting bracket.
 Refit main burner and sole plate(s).
5. To Replace the low fire screw in the gas valve:-
 Remove the oven control panel.
 Remove low fire screw from gas valve and replace with correct
size low fire screw as shown in ‘Gas Specifications Tables’ at
end of this section.
NOTE: The 'Low Fire Screw' should be sealed with coloured
paint on completion of low fire adjustment.
 Refit the oven control panel.
Main Burner Injector
Pilot Burner
Piezo Igniter
Thermocouple
Main Burner
Aeration Slide
Burner Adjustment Screw
Low Fire Screw