Waldorf RNLB8910G Bold 900mm Gas Range Static Oven Low Back Version

Installation Operation Manual - Page 10

For RNLB8910G.

PDF File Manual, 26 pages, Read Online | Download pdf file

RNLB8910G photo
Loading ...
Loading ...
Loading ...
8
Installation
Clearances
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
* Side clearances can be 50mm when adjacent surface is at least 100mm below cooking surface.
Assembly
NOTE:
 All Models are delivered completely assembled. No further assembly is required.
 This appliance is fitted with adjustable feet to enable appliance to be positioned securely
and level. This should be carried out on completion of gas connection. Refer to ‘Gas
Connection’ section.
Optional Accessories (Refer to Replacement Parts List)
 Rear Roller Kit. For installation details, refer to instructions supplied with each kit.
 Plinth Kit. For installation details, refer to instructions supplied with each kit.
1. Check that all feet (or castors) are securely fitted.
2. Adjust feet to make Range steady and level.
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN QUALIFIED PERSON.
1. Waldorf Ranges do not require an electrical connection, as they function totally on the gas supply
only.
2. It is essential that gas supply is correct for appliance to be installed and that adequate supply
pressure and volume are available. The following checks should be made before installation:-
a. Gas Type the appliance has been supplied for, is shown
on coloured stickers located above gas connection point
and on rating plate. Check this is correct for gas supply
appliance is being installed for. Gas conversion procedure
is detailed in this manual.
b. Supply Pressure required for this appliance is shown in
‘Specifications’ section of this manual. Check gas supply to
ensure adequate supply pressure exists.
c. Input Rate of this appliance is stated on Rating Plate and
in ‘Specifications’ section of this manual. Input rate should
be checked against available gas supply line capacity.
Particular note should be taken if appliance is being
added to an existing installation.
NOTE: It is important that adequately sized piping runs directly to connection joint on appliance
with as few tees and elbows as possible to give maximum supply volume.
3. Fit gas regulator supplied, into gas supply line as close to appliance as possible.
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as per ‘Gas Conversion Section’ in this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and it
is NOT to be adjusted.
Fig 1
Rating Plate will be
located in this Area
Combustible Surface Non Combustible Surface
Left / Right hand side 250mm (*) 0mm
Rear 100mm 0mm
Loading ...
Loading ...
Loading ...