Rinnai 8 HotoElectricStorageWaterHeaterOIM
SAVE A SERVICE CALL
Checktheitemsbelowbeforerequestingaservice.Serviceandpartschargesmaybeincurredwhereitisfound
thatthereisnofaultwiththewaterheaterandtheissueisrelatedtotheplumbinginstallationorisduetothefailure
ofwaterorelectricsupplies.
Insu󰀩cientornohotwater
Is the electricity supply
connected?
Checkthattheisolatingswitchmarked“HOTWATER”or“WATERHEATER”atthe
meterboxisswitchedon.Checkalsothatanyisolatingswitchesinstallednearthe
waterheaterareswitchedon.
Checkthefuse orcircuitbreakermarked“HOTWATER” or“WATER HEATER”at
themeterbox.Repeatedfailureoffuseortrippingofcircuitbreakerindicatesafault
whichmustbeinvestigatedbyanauthorisedtradesperson.
IsyourunitaTwinElement
electricwaterheater?
Atwinelementmodel(non-simultaneous)musthaveacontinuouselectricitysupply
tothetopheatingelement.Checkthatthisisthecase.
Are you using more hot
waterthanyouthink?
Oftenitisnotrealizedhowmuchhotwaterisactuallyused.Thisappliesespecially
toshowering.Reviewhotwaterusage,especiallythetimetakenforshowering,and
investigatetheuseofowcontrolvalvesorWatersavingshowerroses.
Are water heater valves
dischargingexcessively?
Refertothesection“SafetyDevices”onpage6.
Thermostatsettings? Checkthetemperatureofhotwaterdeliveredwithathermometerplacedunderthe
closestoutlet(usuallythekitchensink)onanon-temperedhotwaterline.
This test should be done early in the morning after overnight electrical boosting
beforeanyhotwaterisused.Thetemperatureofthewaterdeliveredshouldbeat
least55°C(allowingforheatlossesinpipework).
If this is not the case, the temperature may need to be increased. Contact your
installerorRinnaitodiscussadjustingthethermostat.
Nowaterfromthehottap? Restrictioninthehottaporfailureofthecoldwatersupplytotheheater.
Checkforwaterowattheotherhottapsandthatthecoldwaterisolationvalveis
fullyopen.
HighElectricityBills
Ifyouthinkyourelectricity
bill is too high, check for
thesepossibilities.
If, after investigating, and
you still require assistance
contact Rinnai.
Youmaybeusingmorehotwaterthanyouthink.Thisappliesespeciallytoshowering.
Reviewhotwaterusage,especiallythetimetakenforshowering,andinvestigatethe
useofowcontrolvalvesor‘watersaving’showerroses.Investigaterecentchanges
tohotwaterusagepatterns.
Water heatervalvesmay bedischarging excessively.Refer tothe section“Safety
Devices”onpage6.
Theremaybehotwaterleakagesinhotwaterpipesortaps.Havethesecheckedand
rectiedbyaplumber.
Theremayhavebeenchangesinelectricitytari󰀨ssinceyourlastbill.
PERIODIC MAINTENANCE & SERVICING
Ifoverowtrayanddrainaretted,itistheusersresponsibilitytohavethesecheckedperiodicallytoensurethere
arenoblockages.
TheusershouldoperatetheeasinggearoftheECVandPTRvalve(iftted)every6monthsasdescribedunder
“SafetyDevices”onpage6.
Rinnaiservicenetworkpersonnelarefullytrainedandequipped.IfyourRinnaiappliancerequiresservicingcontact
Rinnaiasperthedetailsonthebackpageofthismanual.Rinnairecommendsthatthiscommercialappliancebe
inspectedandservicedbyaqualiedpersonevery12months.
TheECVandPTRvalveMUSTBEcheckedforperformanceorreplacedbyaqualiedpersonatintervalsnot
exceeding5yearsormorefrequentlyinareaswherethewaterisclassiedasscalingwater.Refertoboththe
“Anode”and“WaterQuality”onpage7forAnodeselection,inspectionandmaintenancerequirements).
Iftheelectricsupplyconduittothewaterheaterisdamaged,itMUSTBEreplacedbyaqualiedpersoninorder
toavoidahazard.
CARE & MAINTENANCE