Rinnai 14 HotoElectricStorageWaterHeaterOIM
ThisapplianceMUSTBEinstalledbyaqualiedpersoninaccordancewith:
Manufacturersinstallationinstructions
CurrentAS/NZS3000WiringRules
CurrentAS/NZS3500.4PlumbingandDrainage-HeatedWaterServices
Alllocalregulatoryrequirements
ThisapplianceisNOTsuitableforuseasaspaorswimmingpoolheater.
LOCATION
TheRinnaiHotoelectricstoragewaterheaterrangehaveaningressprotectionratingofIPX4making80Lto
400Lmodelssuitableforinternalorexternalinstallation.However,Hoto25Land50Lmodelscanonlybeinstalled
indoors.
Thewaterheatershouldbeplacedascloseaspracticabletothemostfrequentlyusedhotwateroutletpointor
pointstominimizethedelaytimeforhotwaterdelivery.Thiswillusuallybethekitchentap.Forinstallationswhere
thedistancebetweenthewaterheaterandtheoutletsisconsiderable,aowandreturnsystemcanbeusedwhich
willminimizethewaitingtimeforhotwaterdelivery.
Itisrecommendedthatthewaterheaterisinstalledatgroundoroorlevel.ItMUSTBEinstalledinavertically
uprightposition.ThewaterheaterMUSTBEaccessiblewithouttheuseofaladderorsca󰀨old.Installationintoroof
spacesMUSTcomplywithlocalregulatoryauthorityrequirements.
EnsurethePTRvalve,isolatingvalves,accesscovers,thermostatsandheatingelementshavesu󰀩cientclearances
andareaccessibleforserviceandremoval.TheinformationontheratingplatesMUSTalsobereadable.
The water heater MUST BE installed in free standing mode on a level and stable base in a manner that is
acceptabletolocalauthorities.Avoidsituationsthatmayresultinpoolingofwateraroundthebaseofthewater
heater.
Wherepropertydamagecanoccurasaresultofwaterleakageinanindoorinstallation,thewaterheaterMUST
BEinstalledwithasafetray(overowtray)anddrain.Construction,installationanddrainingofthesafetrayMUST
complywithlocalregulatoryrequirementsand.AS/NZS3500.4alsorequirestheuseofasafetrayforparticular
situations.
WATER QUALITY
Thewaterqualityofmostpublicsuppliesissuitableforthewaterheater.Waterqualityfromborewellsisgenerally
unsuitable.Refertothe‘WarrantyConditions’forwaterqualityparametersandhowtheya󰀨ectwarranty.Ifindoubt
aboutwaterquality,haveitcheckedagainsttheparameterslistedinthewarrantyconditions.
Ifsludgeorforeignmatterispresentinthewatersupply,asuitablestrainerorltershouldbeincorporatedinthe
watersupplytothewaterheater.
Scalingwaterisdenedashavingatotalhardnessinexcessof200mg/litre(expressedascalciumcarbonate)or
aSaturationIndexinexcessof+0.4.AreasthathaveascalingwatersupplyincludeSouthAustraliaandWestern
Australia.Inascalingwatersupply,calciumcarbonateandpossiblyothercompoundsaredepositedoutofthe
waterontoanyhotmetallicsurfacesandformascale.
InareasofscalingwateranECVMUSTBEttedonthecoldwaterlinebetweenthenon-returnvalveandthe
connectiontothewaterheatertoprotectthePTRvalveandthewaterheater.Localregulatoryauthoritiesmay
requirethatanECVbetted.TheECVistobesuppliedandttedbytheinstaller.
MAINS PRESSURE
TheHotoelectricstoragewaterheaterrangeutilisemainspressurebyconnectingdirectlytothemainswater
supply.IfthemainswatersupplypressureinyourareaexceedstheratedpressureofthewaterheateraPLV
MUSTBEtted.
Themainswatersupplypressureshouldbegreaterthan350kPafortruemainspressureoperationalperformance
tobeachieved.
INSTALLATION