24
Gas Conversion and Specifications
- All Other Markets:
NOTE:
 (*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
 (**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
 Refer to information in this section for further details.
Natural Gas Town Gas (**)
Open Burner
Main Burner Injectors Ø 2.45mm Ø 4.50mm
Pilot Burner ('PF' Models only) 0.30 0.60
Griddle
Main Burner Ø 2.10mm Ø 3.40mm
Pilot Burner 0.35 0.60
Burner Aeration Setting Fully open Fully open
Oven
Main Burner Ø 2.40mm Ø 4.50mm
Pilot Burner 0.35 0.60
Low Fire Ø 0.90mm Ø 1.60mm
Burner Aeration Setting Fully open Fully open
Supply Pressure 1.13 - 3.40 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*) 0.95 kPa 0.63 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to Burner Operating
Pressure specified).
LP Gas (Propane) Butane
Open Burner
Main Burner Injectors Ø 1.50mm Ø 1.40mm
Pilot Burner ('PF' Models only) 0.20
Griddle
Main Burner Ø 1.30mm Ø 1.20mm
Pilot Burner 0.23
Burner Aeration Setting Fully open
Oven
Main Burner Ø 1.40mm Ø 1.30mm
Pilot Burner 0.23
Low Fire Ø 0.55mm
Burner Aeration Setting 10mm
Supply Pressure 2.75 - 4.50 kPa
Burner Operating Pressure (*) 2.6 kPa