30" GAS RANGE INSTALLATION INSTRUCTIONS
(For Models with Electric Ignition or Standing Pilot)
4
C. Level and Position Range - Level range by adjusting
the (4) leveling legs with a wrench. Note: A minimum
clearance of 1/8" is required between the bottom of the
range and the leveling leg to allow room for the
bracket. Use a spirit level to check your adjustments.
Slide range back into position. Visually check that rear
leveling leg is inserted into and fully secured by the
Anti-Tip Bracket by removing lower panel or storage
drawer. For models with a warmer drawer or broiler
compartment, grasp the top rear edge of the range and
carefully attempt to tilt it forward.
2. Provide an adequate gas supply.
This unit is designed to operate on 4" natural gas or 10" LP/
Propane manifold pressure. A convertible pressure regulator
is connected to the manifold and MUST be connected in
series with the gas supply line regardless of which type of
fuel is being used.
Care must be taken during installation of range not to
obstruct the flow of combustion and ventilation air.
For proper operation, the maximum inlet pressure to the
regulator should be no more than 14 inches of water
column pressure. The inlet pressure to the regulator must
be at least 1 inch greater than regulator manifold pressure.
Examples: If regulator is set for natural gas 4 inch manifold
pressure, inlet pressure must be at least 5 inches; if regulator
has been converted for LP/Propane gas 10 inch manifold
pressure, inlet pressure must be at least 11 inches.
Leak testing of the appliance shall be conducted according
to the instructions in step 4g.
The gas supply line should be 1/2" or 3/4" I.D.
3. Seal the openings.
Seal any openings in the wall behind the range and in the
floor under the range after gas supply line is installed.
4. Connect the range to the gas supply.
To prevent leaks, put a pipe joint sealant on all male
(outside) pipe threads.
Your regulator is in one of the two locations shown below.
Do not allow regulator to turn on pipe
when tightening fittings.