Installation
5
Each oven should be connected to an adequately protected
power supply and an isolation switch mounted adjacent to,
but not behind the oven and must be readily accessible to
the operator. This switch must be clearly marked and
readily accessible in case of fire.
Check the electricity supply is correct to as shown on the
Technical Data Plate on the front right hand corner of the
oven side panel.
Ovens Supplied with Cordsets.
1. Ensure that the oven is fitted with the appropriate
power cord and plug.
Ovens Supplied without Cordsets.
NOTE: All electrical connections must only be carried
out by a suitably qualified person.
1. Remove oven rear cover panel.
2. Bring the supply cable up
through the grommet at the
back of oven and through the
compression gland on the
electrical switchgear panel.
3. Connect the mains supply to
the appropriately marked
terminals on the terminal
block.
NOTE:
Fixed wiring installations
must incorporate an
all-pole disconnection
switch.
1. Correctly locate the oven into its final operating position
and using a spirit level, adjust the legs so that the oven
is level and at the correct height.
2. Adjust the oven feet to level the oven.
Before using the new oven;
1. For first time use of the oven, operate the oven for
about 1 hour at 200°C / 400°F to remove any fumes or
odours which may be present.
2. Please refer to the Operation Section of this manual for
details on how to correctly operate and shutdown the
oven.
Grommet
Compression
Gland
This oven must be earthed / grounded.
If the supply cord is damaged, it must be replaced by a
suitably qualified person in order to avoid a hazard.