— 13 —
STEP 12
Connect Ductwork
• Attach ductwork to damper. Secure the ductwork with duct tape to make sure joints are secure and air- tight.
• Donotinstalltheducttapetootightlyasthismaypreventthedamperapsfromopeningwhichwilloverworkthemotor
and cause improper functioning of the unit.
• Fasten all connections with sheet metal screws and tape all joints with certied aluminum or foil tape. Use caulking to
seal exterior wall or roof opening around the cap.
Fig #1
STEP 10
Installing the damper
• Fix the damper on the top vent of hood with 4 screws. (See Figure # 3)
• If ventilation system is equipped with an external air duct with a
different diameter, apply a reduction tting. However, for maximum
performance and safety, a 6” round ducting is recommended.
Fig #3
STEP 11
Mount Range Hood Onto Wall
• Hang the range hood on the hooks of the lower mounting bracket. (See Figure # 4)
• Screw the range hood to the wall. (See Figure # 5)
CAUTION - Make certain the range hood is secure before releasing!
Fig #5Fig #4