2 Pull the back cover and remove it from the appliance.
3 Pull the lter from the appliance.
4 Clean the surface of the lter with a vacuum cleaner.
5 Put the lter back into the appliance.
6 Reattach the back cover.
7 Put the plug of the air purier in the power socket.
8 Touch the button to switch on the appliance.
9 Touch and hold the and button for 3seconds to
reset the lter cleaning time.
10 Wash your hands thoroughly after cleaning the lter.
Replacingthelter
Understanding the healthy protection lock
This air purier is equipped with a lter replacement indicator to make sure that
the air purication lter is in optimal condition when the air purier is operating.
When the lter need to be replaced, the lter replacement alert lights up red.
If the lter is not replaced in time, the air purier will stop operating and
automatically lock to protect the air quality in the room. Replace the lter as soon
as possible.
Replacingthelter
Note:
The lter is not washable or reusable.
Always turn o the air purier and unplug from the
electrical outlet before replacing the lters.
Filteralertlightstatus Action
The lter replacement
alert lights up
Replace the NanoProtect
lter (FY1700/30)
3s
+