16 English
CAUTION
Drain piping connections
Do not connect the drain piping directly to sewage pipes that smell of ammonia. The ammonia in the sew-
age might enter the indoor unit through the drain pipes and corrode the heat exchanger.
8. ELECTRIC WIRING WORK
8-1 General instructions
All field supplied parts and materials and electric works must conform to local codes.
Use copper wire only.
For electric wiring work, refer to also “WIRING DIAGRAM” attached to the unit body.
For remote controller wiring details, refer to the installation manual attached to the remote controller.
All wiring must be performed by an authorized electrician.
A circuit breaker capable of shutting down power supply to the entire system must be installed.
Refer to the installation manual attached to the outdoor unit for the size of power supply electric wire con-
nected to the outdoor unit, the capacity of the circuit breaker and switch, and wiring instructions.
Be sure to ground the air conditioner.
Do not connect the ground wire to gas pipes, plumbing pipes, lightning rods, or telephone ground wires.
Gas pipes: might cause explosions or fire if gas leaks.
Plumbing: no grounding effect if hard vinyl piping is used.
Telephone ground wires or lightning rods: might cause abnormally high electric potential in the ground
during lighting storms.
Fig. 24
Control box cover
Ground
terminal
Power supply
wiring terminal
block
Power supply
single phase 208/230V
L
2
L
1
Ground
wire