Operation Ranges
English
AppendixAppendixAppendixAppendix
Operation Ranges
The table below indicates the temperature and humidity ranges the air conditioner can be operated within.
Refer to the table for efficient use.
MODE
OPERATIONAL TEMPERATURE
INDOOR
HUMIDITY
IF OUT OF CONDITIONS
INDOOR OUTDOOR
COOLING 18 ˚C to 32 ˚C
Depends
on the
specifications
of the outdoor
unit.
80 % or less
Condensation may occur on the indoor
unit with risk to have either water blow
off or drops on the floor.
HEATING 27 ˚C or less -
Internal protection triggers and the air
conditioner will stop.
DRYING 18 ˚C to 32 ˚C 80 % or less
Condensation may occur on the indoor
unit with risk to have either water blow
off or drops on the floor.
NOTE
The standardized temperature for heating is 7 ˚C. If the outdoor temperature drops to 0 ˚C or below, the
heating capacity can be reduced depending on the temperature condition.
If the cooling operation is used at over 32˚C (indoor temperature), it does not cool at its full capacity.
Information about Refrigerant
Important information: regulation regarding the refrigerant used
This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere.
CAUTION
If the system contains 5 tCO₂e or more of fluorinated greenhouse gases, it must be checked for leakage
at least once every 12 months, according to regulation No. 517/2014. This activity must be covered by
qualified personnel only. In the case of the situation above, the installer (or authorized person with
responsibility for final check) must provide a maintenance book, with all the information recorded,
according to REGULATION (EU) No. 517/2014 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of
16 April 2014 on fluorinated greenhouse gases.
Refrigenat type GWP value
R-410A 2088
GWP: Global Warming Potential
Calculating tCO₂e: kg x GWP/1000