VI. DEFLATION OPERATION
Remove the hose from the inflation inlet. Connect the end with flexible conduit
adaptor (11) of the hose with the air pump deflation outlet (2), and twist clock
wise to tighten it, as Figure 3,and the other end shall still be to the airbag.
Press the button of the power switch of air pump, and start the deflation
until all the gas is discharged, then the power can be turned off to stop the
deflation.
VI. PRECAUTIONS
The applied power source must be the 12V DC power source (as Figure 4).
Do not block the inflation inlet (1) and Deflation outlet (2), and ensure that the
inflation inlet (1) and Deflation outlet (2) shall remain smooth at all times.
Observe the local waste treatment provisions, and it is not allowed to throw
the air pump away randomly.
Don't use this product when the hose is damaged, and please change the hose
immediately.
Don't pull out the hose when inflating, because that the high pressure may hurt
the physical body.
Don't make the air pump work for more than 20 minutes, because that motor
overheating may cause internal damage; and the air pump shall be fully cooled
for 30 minutes after continuously working up to 20 minutes.
www.SereneLifeHome.com
6
Please don't use this air pump if any part is damaged, and please contact with
the professional personnel to repair it.
This product shall not be exposed to the rain or immersed in water. In order to
prevent risk, the inflation inlet shall not be forward to face or body.
Please don't not leave while inflating.
Please start the car when using the product, in case of unnecessary damage.
VII. FAULT HANDLING
VIII. MAINTENANCE AND STORAGE
After using, or if you want to move, maintain or adjust the product, please first
pull out the DC plug from the socket.
When it is idle, it shall be properly stored after being fully cooled.
It shall not be exposed to the rain or immersed in water.
Please store it in the dry and ventilated place.
Figure 3
Fault Inspection Solution
The air pump
cannot be started
normally.
1. The power source
is not plugged
properly.
2. The fuse in DC
plug (7) is burnt
out.
3. Overheating or
overload causes
motor stop.
1. Make sure that the power
wire is plugged in the 12V
DC socket.
2. Change the fuse.
3. Cool the motor and restart it.
4. If the problem cannot be
solved, please contact with
the manufacturer or its
service agent or the similar
authorized personnel.
Slow or abnormal
inflation.
1. Check whether
the hose is blocked
or cracked.
2. The joint between
the hose and air
pump or air bag is
not installed
properly.
1. Change the hose or make it
unblocked, and check
whether the hose is cracked.
2. Reinstall the hose.
3. If the problem cannot be
solved, please contact with
the manufacturer or its
service agent or the similar
authorized personnel.