clothes, please rinse with plenty of water as soon as possible; if you find a leak, please do not use the remote
control.
If you swallow the battery liquid, rinse your mouth and seek medical attention as soon as possible. The
chemical substances in the battery may burn or cause other health hazards.
SAFETY PROTECTIONS
1. Water-full safety alarm and shut off protection function
When the water volume exceeds its alarm level in chassis, warning sounds automatically and water-full icon is lighting in
display, you need to drain the water and re-start the unit. (For more information about how to drain, refer to the “Drainage
Instruction” please). If the unit is not shut down manually, the unit will recover to the original operating status
automatically once the water is fully drained. Or connect the power to re-start the unit again.
2. Anti-frozen protection function
Under COOLING mode, when the compressor continuously runs over 10 minutes, if tube temperature is ≤2 ºC /36 ºF
for 20 seconds, the anti-frozen protection function will be on, E4 will be shown on LED display, compressor and water
wheel motor will stop working, but upper fan remains running; If tube temperature ≥8 ºC /46 ºF, the unit will stop
anti-frozen protection and recover to the original working condition. Compressor will re-start working with 3 minutes
delay for protection.
3. Delay protection function of compressor
This unit offers restart protection to compressor. Except that the compressor may start immediately when the unit is
energized first time, there is 3-minute delay re-start protection after compressor is shut down.
4. Coil and room temperature sensor failure:
1) Detect sensor failure at the beginning of power-on or power-on state
2) When a sensor failure is detected at the beginning of power-on, it will immediately enter the failure state. If it
returns to normal at this time, it will enter the standby state;
AIR CONDITIONER USE
IMPORTANT: If the air conditioner has been tilted on its side, wait 24 hours before turning on the air conditioner to allow
the oil to return to the compressor. This will prevent the air conditioner from failing prematurely.
Hold handles on side panels to move the unit in upright position.
NOTE:
Do not hold the louver.
Make the unit in the upright position whatever handling or moving it.
Drain the water in the unit completely to prevent water leakage and wet the floor or carpet before handling or
moving the unit.
DRAIN THE INTERNAL WATER
You will need a small pan to catch the water coming out of the water tank. Once the water tank is empty, the unit will
resume operation within a few minutes.
MANUAL DRAINAGE
1. Once the unit shuts down upon water-full, turn off the unit and then unplug.
2. Put the tray below the water outlet at the back of the unit.
3. Screw off the drain cover, unplug the water stopper for water flow into the tray.
4. Plug in stopper and screw the drain cover tightly onto water outlet after drainage.