7
INSTALLATION
Installing the Range Hood
Note
If the wood hood is enclosed at the bottom, make a cutout on the board so that the Range Hood can fit into the wood
hood.
Guide the duct into the Wood Hood. Temporarily secure the top of the duct to the ceiling opening or wall opening.
Electrical Connection
This range hood comes with a power cord with a 3-prong plug. Connect the power cord to a designated grounded
standard 110V outlet.
WARNING
Electrical Shock Hazard
Disconnect power before servicing
Figure 2
The following steps requires 2 or more people:
Unpack the Range Hood and place it on a sturdy flat surface
with the Baffle Filters facing the ceiling.
Remove the Baffle Filters. (
Step1 & 2 in Figure 1
)
Remove the bottom cover and put it in a safe location.
Connect the duct to the vent opening on the Range Hood.
If the duct size isn't the same as the vent opening, use an
adapter between the duct and the vent opening.
While lifting the Range Hood to fit into the wood hood, retract
the Duct into the attic carefully.
Insert and tighten all screws into the pre-drilled holes on the
Hood body until it is securely mounted to the wood hood.
(
Figure 2
)
Release the Range Hood.
Put the Panel back and tighten all screws.
CAUTION
Make sure the Hood Unit is securely mounted before
releasing.
Route and connect the Duct to the Roof or Wall Cap. Refer to Page
5 for the most efficient routing requirements.