Loading ...
Loading ...
Loading ...
INSTALLATION INSTRUCTIONS
10
Recirculate with
carbon filters
Recirculating
Check with local codes and regulations if recirculation is allowed in
your area.
IMPORTANT!
Venting directly into the cabinet with no ducting and louvered vent is not permitted.
To recirculate your perimeter insert range hoods:
Determine the desired location of the 150mm louvered vent on your cabinetry.
The louvered vent can be placed on the side or front of your cabinet provied there is
sufficient clearance form the surrounding cabinetry to enable ventilated air to recirculate
back into your kitchen.
Note: Placement of the louvered vent on the top of your cabinetry is not recommended.
This should be only be done if objects can be prevented from falling through the louvers
in to the blower.
Create a cutout in your cabinet to fit the 150mm louvered vent. Place the louvered vent
on the hole created and secure (A).
Connect the blower outlet to the louvered vent with a length of 150mm rigid ducting,
and secure the joints with aluminum tape. Ensure there is no slack in the ducting.
Recirculation venting options
WARNING!
This appliance is heavy and requires two persons for unpacking and installation.
Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards.
Failure to install the screws or fixing device in accordance with these instructions
may result in electrical hazards.
IMPORTANT!
Wear gloves to protect against sharp edges.
The manufacturer is not liable for any damage caused by not following these instructions.
Where ducting outside is not a practical option, this rangehood can be
installed to operate with the air recirculating. Carbon filters are
required to remove odours from the air before it is channelled back
into the room or overhead bulkhead (refer to ‘Cleaning and Mainte-
nance’ section).
Ensure that the ducting outlet is not obstructed, even a partial
obstruction will restrict the efficiency of the rangehood.