Asko HID654GC

Product/manual/usage connection installation - Page 54

For HID654GC.

PDF File Manual, 62 pages, Read Online | Download pdf file

HID654GC photo
Loading ...
Loading ...
Loading ...
The following connections are possible.
1 phase, 1 neutral conductor (220240 V~, 50-60 Hz)
To reach the rated maximum power a fuses of 32A is needed.
Install a jumper between terminals 1 and 2 and between terminals 4
and 5.
2 phases, 1 neutral conductor (380415 V 2N~, 50-60 Hz)
To reach the rated maximum power two fuses of 16A are needed.
Install a jumper between terminals 4 and 5.
(only for NL)
2 phases, 2 neutral conductors (220240 V 2-2N~, 50-60 Hz)
To reach the rated maximum power two fuses of 16A are needed.
The 2 fases (L1 and L2) should be secured by only one and the same
earth leakage breaker. It is not allowed to run L1/N1 threw a different
earth leakage breaker than L2/N2.
For appliance types: BI9CA, BI9CB, BI9CC .
NOTE!
Note: The appliance type can be found on the rating plate on the bottom of the appliance.
Voltage between line and neutral conductor must be 220240 V~. Voltage between lines must be
380415 V~. Power cord core cross sectional area should be at least as listed in Table for the
following current limiter settings which should be adjusted to your circuit breakers:
Number and cross section
of Power cord wires
Power cord
type
Connection typeCurrent limiter
settings
5x1,5 mm²H05V2V2-F3 phases, 1 neutral conductor3x16A
5x1,5 mm²H05V2V2-F3 phases, 1 neutral conductor3x13A
5x1,5 mm²H05V2V2-F3 phases, 1 neutral conductor3x10A
5x1,5 mm²H05V2V2-F3 phases, 1 neutral conductor3x06A
4x1,5 mm²H05V2V2-F2 phases, 1 neutral conductor2x16A
4x1,5 mm²H05V2V2-F2 phases, 1 neutral conductor2x13A
4x1,5 mm²H05V2V2-F2 phases, 1 neutral conductor2x10A
54
Electrical installation
Loading ...
Loading ...
Loading ...