Loading ...
Loading ...
Loading ...
34
Converting Appliance for Use with Natural
Gas
If this appliance should be converted for use with Natural gas, each of the following modifications must be performed.
1) Convert the pressure regulator to NG position as per the section “Pressure Regulator Conversion”.
2) Replace all injectors following the step described on the previous pages, observe the number stamped on the side, this
number corresponds to the orifice diameter and its correct burner location (refer to the illustrations in section: “Injectors
Position”).
3) Adjust the burner flame (see Low Flame Adjustment section). Check the appearance of each burner’s flame at HI - LO
settings, if the flame appears too large or too small make sure that all steps were completed correctly.
Pressure Regulator Conversion
The appliance is designed for use with NG gas or LP gas. The gas pressure regulator is supplied. It must be installed in the
gas supply line ahead of the manifold entrance.
It is pre-set for use with the gas as indicated on the appliance label supplied with the appliance. For use with dierent gas the
appliance must be converted.
For the pressure regulator conversion follow the instructions below:
Disconnect all electrical power, at the main circuit breaker or fuse box.
Shut o the gas supply to the cooktop by closing the manual shut-o valve.
Adjust the pressure regulator, by following the instruction. (see figure for conversion from NG gas to LP gas)
1) Unscrew the regulator cap. (figure2)
2) Overturn and screw the cap back on (from NG gas to LPG gas, see figures 4,5).
3) Replace the regulator cap ensuring gasket is in place (figures 6,7).
Loading ...
Loading ...
Loading ...