28
beep sound as a reminder whenever the data reading reaches the preset
minimum or maximum point.
To set threshold limits for the parameter values
1. Tap the Setting function button at the bottom of the Live Data screen.
2. Tap the Selected navigation button.
3. Select a parameter item on the left column or enter the item name in the Search
bar.
4. Tap on the right side of the MIN button and enter the required minimum value.
5. Tap on the right side of the MAX button and enter the required maximum value.
6. Tap the ON/OFF button on the right side of the Buzzer Alarm button to turn it on
or off.
7. Tap Done to save the setting and return to the Live Data screen; or tap Cancel
to exit without saving.
If the threshold limits are successfully set, two horizontal lines will appear on each of the
data graphs (when Waveform Graph Mode is applied) to indicate the alarming point. The
threshold lines are shown in different colors from the waveform of the parameters for
distinction.
Record Button displays the configuration screen for Record Setting, on which you
can set the trigger type, duration and trigger point for the data recording function.
a) Trigger Type sets the trigger mode for data recording, mainly of two kinds:
Manual and Auto. There are four options available:
1) Manual allows you to manually start and stop data recording.
2) DTC auto triggers data recording when any DTC is detected.
3) DTC Check Mode auto triggers data recording when certain pre-selected
DTC types are detected.
4) Parameter auto triggers data recording when any parameter value
reaches the preset threshold.
b) Duration sets the recording time (for Auto trigger mode only).
c) Trigger Point reserves a relative percentage of a record length before the
data recording start point for reference (for Auto trigger mode only).
To perform setting for live data record
1. Tap the Setting function button at the bottom of the Live Data screen.
2. Tap the Record navigation button.
3. Tap the button on the right of Trigger Type bar and select the required
trigger mode.
4. Tap the button on the right of Duration bar and select a length of time.
5. Tap the button on the right of Trigger Point bar and select a relative
percentage of a record length to be reserved before the data recording start
Loading ...