Pure Guardian H955W 30-Hour Ultrasonic Top Fill Cool Mist Humidifier

USE & CARE INSTRUCTIONS - Page 6

For H955W.

PDF File Manual, 24 pages, Read Online | Download pdf file

H955W photo
Loading ...
Loading ...
Loading ...
E-6
GENERAL CLEANING
1. Always unplug the unit before servicing in any way.
2. Water tank. Empty the tank to clean. Clean the inside of the tank with fresh water and a soft
cloth or the cleaning brush. To clean the inside of the upper mist tube (inside the tank) first
remove the mist spout by pulling it directly off. Then twist the mist tube in a counter clockwise
direction and pull it out. To remove the lower mist tube (underside of the tank) twist it in a counter
clockwise direction and pull it out. Clean the insides of both pieces with a brush and water.
Return both pieces by rotating them in a clockwise direction until snug and then snapping the
mist spout back onto the upper mist tube. When returning tank to base, position the tank by
aligning the two lines on the side of the tank.
3. Outer surface of the unit. Wipe the lid and surface of the unit with a soft, damp cloth if needed.
If you notice an accumulation of water during usage, reduce humidity and dry outer surface
with a cloth.
DESCALING
• Depending on usage and water type, cleaning to remove scale may be required weekly or every
other week to optimize unit performance.
• If you live in a hard water area, we recommend the use of distilled water for your humidifier.
This will help reduce the precipitation of minerals or ‘white dust’.
• Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.
ULTRASONIC DISK
1. Unplug unit.
2. Empty the tank and any remaining water in the
base of the tank by pouring out all of the water.
3. Locate the ultrasonic disk on the
inside center of the base unit.
4. Use ONLY the enclosed cleaning brush to gently
clean disk and remove build up and deposits.
Do not scrub or scrape the ultrasonic disk.
Ultrasonic Disk Clean the disk with the brush only. No other
cleaning tool should be used. BRUSH ONLY.
If scale becomes difficult to remove with brush:
1. Fill the tank with: mixture of 1 tsp. white vinegar and 1 tsp. water.
2. Let solution stand for 5 minutes.
3. With the vinegar in the tank, clean all interior surfaces with a soft cloth or brush to help
remove scale.
4. Also check mist nozzle and mist tube in water tank. Clean as needed.
5. Rinse the tank thoroughly with water to remove scale and vinegar solution.
END OF SEASON STORAGE
Follow the Cleaning and Descaling instructions when the humidifier will be stored at the end
of the season.
Dry the humidifier completely before storing. DO NOT store with water inside the Base or
Water Tank.
Pack the unit in its original carton and store in a cool, dry location.
NOTE: IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOTOR
HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE
TO THE HUMIDIFIER OR PERSONAL INJURY.
Looking down
at the inside of
empty base.
Loading ...
Loading ...
Loading ...