Pure Guardian H955W 30-Hour Ultrasonic Top Fill Cool Mist Humidifier

USE & CARE INSTRUCTIONS - Page 5

For H955W.

PDF File Manual, 24 pages, Read Online | Download pdf file

H955W photo
Loading ...
Loading ...
Loading ...
E-5
3. Return the tank lid.
FILLING - Make sure unit is unplugged.
DIRECTIONS FOR USE
1. Remove the tank lid.
2. Pour cool, clean water directly into the tank,
or lift handle in tank and carry to sink to fill.
Fill to MAX line on Mist Tube.
4. OPTIONAL: Add a few drops of your favorite essential oil to directly to the tank. (Oil not included)
NOTE: Essential oils can be added directly to this water tank due to the material used in the design.
5. WATER REFILL INDICATOR - When the unit is low on water the power button will flash red
and the display will show E1 until the unit is refilled or turned off. Add more water to continue use.
Unit will automatically resume running when the tank has been refilled.
CONTROL OPERATION
Power Button - Press to turn the power on/off.
Timer - Set the scheduled shutdown time from 1 to 12 hours shown on the display, the
product will shut down after the timer expires. The display will read "CO", press the timer
button to set the timer for the hour time preferred.
Night light - Press once to turn on the 7 color night light. Continue to press up to 8 times
to circulate through and select a color. The 9th press turns the light off.
Humidity Setting - Press to select the preferred humidity level. The humidity range can
be set from 40% to 75%RH. Recommended humidity is between 45-50%. When ambient
humidity reaches the select setting the unit will work in low speed. If it falls +/- 5% it will
restore to the original speed.
AUTO Mode - Press to turn on/off Auto function. This function changes the mist output
based on the following:
Default humidity upper limit is 50%RH
1. When 40%RH
<
current humidity
<
50%RH, low mist output
2. When 30%RH
<
current humidity
40%RH, medium mist output
3. When the current humidity
30%RH, high mist output
4. When the current humidity is
50%RH, the transducer will automatically stop working
but the fan will still work, the unit will resume work until the current humidity
<
50%RH
Mist Output - Press to select speed: 1-3.
AUTO
When the tank is removed or the tank is not properly aligned, the power button will light up
(solid red), the display will show E2. Realign tank by matching the small lines on the side
of the tank and base.
Loading ...
Loading ...
Loading ...